Dehumidifier Size Calculator

A 1,000 sq ft basement that feels damp only in humid weather needs a 10 pint dehumidifier on the current label (14 pints on a pre-2019 label); a wet one, with sweating walls or seepage, needs 14 pints (20 on the older label). Enter your floor area, ceiling height and how damp the space is below.

Jump to your result ↓

Your project

Results

Example job shown. Change the numbers to match yours.

Capacity to shop for (current label)
10 pints/day
Older labels, before 2019: 14 pints/day
Capacity on an older label
14 pints/day
Moisture to removeOlder (80°F, 60% RH) test conditions
6.6 liters/day
  • Capacity is based on the long-standing Energy Star and AHAM sizing chart for a 500 to 2,500 ft² space at 80°F and 60% humidity, extended in a straight line outside that range. Since 2019 the US test is run at cooler 65°F, so a unit now carries a lower number: the same machine is rated about 30% fewer pints than before.

Before you buy: round up to whole packs, check the size printed on the label, and add a little spare. Your supplier has the final say.

How this calculator works

A dehumidifier is sold by how many pints of water it removes from the air in 24 hours. The amount you need depends on the size of the space and how much moisture is coming into it. The standard sizing chart gives four levels of dampness, and each one rises in a straight line with floor area: more floor means more moisture to remove.

pints per day = (base + step × (area − 500) ÷ 500) × (ceiling ÷ 8) + extras

The base and step are 10 and 4 for a moderately damp space, 12 and 5 for very damp, 14 and 6 for wet and 16 and 7 for extremely wet. A taller ceiling means more air, so a ceiling over 8 ft scales the answer up in proportion.

Worked example: a 1,000 ft² basement that feels damp in humid weather needs 10 + 4 × (1,000 − 500) ÷ 500 = 14 pints per day on the older rating. The 2019 test conditions are less generous, so the same job shows as about 14 × 0.7 = 10 pints on a current label. Machines are sold in set sizes, so pick the next size up.

Assumptions and sources

The assumptions behind your numbers (waste, sizes, rates) are listed in the notes directly under your results, and they update when you change an input.

The formula and a worked example are shown above, so you can check any result by hand. Read how we calculate and check our numbers. Results are estimates for planning: supplier products vary, so check the size printed on the label.

Pints per day (older rating) by area and dampness, 8 ft ceilings

Multiply by about 0.7 for the number on a current label.

Floor areaModerately dampVery dampWetExtremely wet
500 ft²10121416
1,000 ft²14172023
1,500 ft²18222630
2,000 ft²22273237
2,500 ft²26323844

Dehumidifier size chart, current (2019 and later) label

Pints per day for 8 ft ceilings. New units are rated at 65°F and 60% humidity, so the same machine shows a smaller number than on the older 80°F label.

Floor areaModerately dampVery dampWetExtremely wet
500 sq ft7 pints9 pints10 pints12 pints
1,000 sq ft10 pints12 pints14 pints17 pints
1,500 sq ft13 pints16 pints19 pints21 pints
2,000 sq ft16 pints19 pints23 pints26 pints
2,500 sq ft19 pints23 pints27 pints31 pints

Tips before you buy

  • If you are between two sizes, buy the larger one. A dehumidifier that is too small runs all day and never reaches the target, while a bigger one reaches it, then rests.
  • Aim for 30 to 50% relative humidity, and under 60% always. A cheap hygrometer tells you what the room is actually doing.
  • A unit with a built-in pump or a drain hose connection saves emptying the bucket, which matters in a basement where it runs for days.
  • Fix the cause as well. Gutters and downspouts that send water away from the foundation, a sealed dryer vent and a vapor barrier on a crawl space remove moisture the dehumidifier would otherwise have to handle.
  • Dehumidifiers work poorly in cold rooms: below about 60°F the coils frost up. For a cold basement, a model rated for low temperatures is worth the extra cost.
  • Set the humidity target, then check the water filter and coils every month or so to keep it running efficiently.

Tools & materials for this project

Affiliate links As an Amazon Associate we earn from qualifying purchases. These links do not change what you pay.

Frequently asked questions

What size dehumidifier do I need for a 1,000 square foot basement?

About 14 pints per day on the older rating if it is only moderately damp, 17 if it is very damp, and 20 if it is wet. On a current label these are about 10, 12 and 14 pints. Machines are sold in set sizes, so choose the next size up.

What size dehumidifier do I need for a 2,500 square foot house?

A moderately damp space of 2,500 ft² needs about 26 pints per day on the older rating, and an extremely wet one 44. On a current label that is about 19 to 31 pints. Larger models, around 50 to 70 pints, are common for big basements.

What changed with dehumidifier ratings in 2019?

The US Department of Energy moved the test from 80°F and 60% humidity to a cooler 65°F, which is closer to a real basement. The same machine is now rated about 30% fewer pints, so a 50-pint unit from before is a 35-pint unit today.

Is it OK to buy a bigger dehumidifier than I need?

Yes. A larger unit reaches the target humidity sooner and then switches off, so it does not run all day. Compare the energy efficiency (liters per kWh) on the Energy Star label, because bigger is not always less efficient per pint removed.

What size dehumidifier do I need for a 1,500 sq ft basement?

13 pints a day on the current label (18 on an older one) if it is moderately damp, and 19 pints if it is wet. Fix any water coming in first: a dehumidifier handles damp air, not leaks.

Add this calculator to your website

Running a blog, a contractor site or a class page? You can put this calculator on it for free. Copy the code below, and please leave the link underneath the calculator in place. The small script just resizes the frame to fit the results; if your site strips scripts, the calculator still works inside a scrolling frame.

Get the embed code

Related calculators & guides

Estimates only. Results assume standard materials and simple shapes. Supplier products vary, and the final call on quantity, structure and safety is yours. Check your local code and your supplier's guidance before ordering.