Insulation depth to add, by current and target R-value
Depths are for blown fiberglass at R-2.5 per inch, in a 1,800 sq ft attic. Loose-fill settles, so add a small allowance, and keep it clear of the soffit vents with baffles.
| You have now | To R-30 | To R-38 | To R-49 | To R-60 |
|---|---|---|---|---|
| None (bare floor) | 12.0 in | 15.2 in | 19.6 in | 24.0 in |
| R-11 | 7.6 in | 10.8 in | 15.2 in | 19.6 in |
| R-19 | 4.4 in | 7.6 in | 12.0 in | 16.4 in |
| R-30 | none needed | 3.2 in | 7.6 in | 12.0 in |
Which insulation, going from R-11 to R-49
The R-value you add is the same, but the thickness and the volume change with the type of insulation. Spray foam is much thinner for the same R-value but costs more.
| Type | R per inch | Depth to add | Volume to buy |
|---|---|---|---|
| Blown fiberglass | R-2.5 | 15.2 in | 2,280 cu ft |
| Fiberglass batts | R-3.2 | 11.9 in | 1,781 cu ft |
| Blown cellulose | R-3.5 | 10.9 in | 1,629 cu ft |
| Open-cell spray foam | R-3.7 | 10.3 in | 1,541 cu ft |
| Closed-cell spray foam | R-6.5 | 5.8 in | 877 cu ft |
Use the attic insulation calculator for your own attic, and read how much attic insulation you need for climate-zone targets. Seal air leaks first, and check attic ventilation before you add more.
Want to change anything else? The calculator above is the full Attic Insulation Calculator: edit any number and the results update instantly.
Tools & materials for this project
Affiliate links As an Amazon Associate we earn from qualifying purchases. These links do not change what you pay.
Frequently asked questions
How many inches of insulation does a 1,800 sq ft attic need?
From R-11 to R-49 with blown fiberglass (R-2.5 per inch) you add about 15.2 inches. From a bare floor it is 19.6 inches. The depth is the same for any attic size: the area only changes how much material you buy.
How much insulation do I need to buy for a 1,800 sq ft attic?
About 2,280 cubic feet of blown fiberglass to go from R-11 to R-49. Check the coverage chart on the bag: it lists bags needed at each depth, and settling means you should buy a few extra.
Is R-38 enough for a 1,800 sq ft attic?
R-38 is a common recommendation for milder climates, and from R-11 it means adding 10.8 inches of blown fiberglass (1,620 cu ft). Cold climates are better at R-49 to R-60. Check your climate zone in the calculator.