Outlets Per Room Calculator: How Many Receptacles Does Code Require?

Enter the size of the room and its doorways. You get the least number of wall outlets the National Electrical Code asks for in a living room, bedroom, den or similar room: none more than 12 ft apart, and no point on the wall more than 6 ft from one.

Jump to your result ↓

Your project

Doors, wide archways and sliding glass doors break the wall into separate wall spaces.

A standard door is about 3 ft. A wide archway is more.

Results

Example job shown. Change the numbers to match yours.

Outlets for a typical layout (wall by wall)
6 outlets
Each wall space of 2 ft or more gets at least one, and no more than 12 ft between them
Absolute minimum (if the wall space were one unbroken run)Only possible if the layout lets one outlet serve two walls around a corner
4 outlets
Wall length round the room
52.0 ft
Wall length left after the doorways
46.0 ft
Spacing if outlets are evenly spread (typical layout)Never more than 12 ft apart
7.7 ft
  • Under NEC 210.52(A), receptacles in the wall spaces of a living room, bedroom, dining room, den and similar rooms must be placed so that no point along the floor line of a wall is more than 6 ft from an outlet, which in practice means no more than 12 ft apart. A wall space is 2 ft or more of unbroken floor line; fixed room dividers and bar-type counters count. The result is a planning minimum: we spread the doorways over the walls in proportion to their length, so move them to where yours are and recount for an exact layout. Kitchens, bathrooms, hallways, garages and outdoor areas have their own rules, local codes add to the NEC, and more outlets than the minimum are almost always worth having. Have the work done or checked by a licensed electrician.

Before you buy: round up to whole packs, check the size printed on the label, and add a little spare. Your supplier has the final say.

How this calculator works

The National Electrical Code (NEC 210.52(A)) asks for wall outlets in living rooms, bedrooms and similar rooms so that no point along the floor line of any wall is more than 6 ft from one. Put another way, outlets are no more than 12 ft apart, and any wall space of 2 ft or more gets an outlet. Doorways and other openings that reach the floor split the walls into separate wall spaces, each counted on its own.

outlets for a wall space = ⌈wall space length ÷ 12 ft⌉, at least 1 if the space is 2 ft or more

Worked example: a 14 × 12 ft room has 52 ft of wall. Two 3 ft doorways leave 46 ft of wall space. Counted wall by wall (doorways spread in proportion to the wall lengths) that is 6 outlets; if the wall space were one unbroken run, the absolute least would be 4. With no doorways at all the walls give 6. A large 24 × 16 ft room needs 8.

Assumptions and sources
  • Under NEC 210.52(A), receptacles in the wall spaces of a living room, bedroom, dining room, den and similar rooms must be placed so that no point along the floor line of a wall is more than 6 ft from an outlet, which in practice means no more than 12 ft apart. A wall space is 2 ft or more of unbroken floor line; fixed room dividers and bar-type counters count. The result is a planning minimum: we spread the doorways over the walls in proportion to their length, so move them to where yours are and recount for an exact layout. Kitchens, bathrooms, hallways, garages and outdoor areas have their own rules, local codes add to the NEC, and more outlets than the minimum are almost always worth having. Have the work done or checked by a licensed electrician.

The formula and a worked example are shown above, so you can check any result by hand. Read how we calculate and check our numbers. Results are estimates for planning: supplier products vary, so check the size printed on the label.

Minimum wall outlets by room size (two 3 ft doorways)

The typical wall-by-wall count from this calculator.

RoomOutlets (wall by wall)Absolute minimum
10 × 10 ft43
12 × 10 ft44
12 × 12 ft44
14 × 12 ft64
16 × 12 ft65
20 × 14 ft86
24 × 16 ft87

Tips before you buy

  • The 12 ft rule is a maximum. Most electricians put an outlet on every wall space of a few feet or more, and add more where you will plug in a desk, TV or bedside lamps.
  • Count wall space along the floor, not the ceiling. A doorway, a floor-length window or a wide archway ends one wall space and starts another.
  • Many areas require tamper-resistant outlets in living areas, and arc-fault breaker protection on bedroom circuits. Check which edition of the NEC your area has adopted.
  • Rooms behind a door count separately: a closet or a hallway follows its own rule.

Tools & materials for this project

Affiliate links As an Amazon Associate we earn from qualifying purchases. These links do not change what you pay.

Frequently asked questions

How many outlets are required in a room?

One on every wall space of 2 ft or more, and never more than 12 ft apart, so no point on the wall is more than 6 ft from one. A 14 × 12 ft room with two doorways needs about 6.

What is the 12 foot rule for outlets?

The NEC wall-outlet rule: receptacles are placed so no point along a wall is more than 6 ft from one, which means they are no more than 12 ft apart.

How many outlets can be on one circuit?

The NEC does not set a number for a 15 or 20 amp household circuit: the limit is the circuit load. Use the circuit capacity calculator to check what a circuit can carry.

Does a doorway count as wall space?

No. A doorway breaks the wall: wall spaces on either side are counted separately, and a wall space is 2 ft or more of unbroken floor line.

Do these rules apply to kitchens and bathrooms?

No: kitchen counters, bathrooms, hallways, garages and outdoor areas have separate rules, and they usually require GFCI protection. This calculator is for living rooms, bedrooms, dens and similar rooms.

Add this calculator to your website

Running a blog, a contractor site or a class page? You can put this calculator on it for free. Copy the code below, and please leave the link underneath the calculator in place. The small script just resizes the frame to fit the results; if your site strips scripts, the calculator still works inside a scrolling frame.

Get the embed code

Related calculators & guides

Estimates only. Results assume standard materials and simple shapes. Supplier products vary, and the final call on quantity, structure and safety is yours. Check your local code and your supplier's guidance before ordering.