What Size Generator to Run a Central Air Conditioner?

A central air conditioner needs about 3,500 running watts and 10,500 watts to start, so on its own you should shop for a generator rated for about 9,000 running watts, which includes at least 20% headroom.

Jump to your result ↓

Your project

W
W

The surge above running watts for the biggest motor, from its label.

Results

Example job shown. Change the numbers to match yours.

Generator size to shop for
9,000 running watts
At least 20% headroom. Portable (conventional) models are common at this size
Total running watts
3,500 W
Peak watts at startup
10,500 W
Running load at 240 V (transfer switch estimate)Estimate only: an electrician sizes the transfer switch and circuits for your panel
14.6 amps
Appliances selected
1 item
  • Start the biggest motor first, and add loads one at a time. Wattages are typical and the starting figures are on the cautious side (published charts differ: a 3-ton central air conditioner is listed anywhere from 5,000 to about 12,000 starting watts, and refrigerators from 800 to 2,200), so check each appliance label (a W or A rating) and use that if it differs. An inverter generator runs electronics more safely than a conventional one.

Blueprint

3k5k7.5k10k15k10,500

10,500 W starting · 3,500 W running

Generator size for a central air conditioner

These use typical wattages (running and starting), plus at least 20% headroom on the running load. Your appliance's label is the best guide.

What you runRunningPeak at startupGenerator to shop for
Central air conditioner alone3,500 W10,500 W9,000 running watts
+ refrigerator, lights, laptop and router4,450 W11,450 W11,000 running watts
+ the essentials (fridge, sump pump, furnace blower, lights, laptop)6,050 W13,050 W11,000 running watts

Motors need a surge when they start, which is why the starting watts are higher than the running watts. Build your list in the generator size calculator, and see the generator sizing guide for safety (never run a generator indoors) and how to connect it properly.

How to connect it

This appliance is 240 V and hard-wired. Central air is hard-wired, 240 V, and has a very large starting surge. It needs a transfer switch and a large generator. A soft-start device can cut the surge a lot. It draws about 14.6 amps running at 240 V.

Always run a generator outdoors, well away from windows and doors, and use battery-powered carbon monoxide alarms inside. See the generator guide for the full safety list.

Want to change anything else? The calculator above is the full Generator Size Calculator: edit any number and the results update instantly.

Tools & materials for this project

Affiliate links As an Amazon Associate we earn from qualifying purchases. These links do not change what you pay.

Frequently asked questions

What size generator do I need to run a central air conditioner?

A central air conditioner needs about 3,500 running watts and 10,500 watts at startup, so shop for a generator rated for about 9,000 running watts if it is the only thing you run. Add the watts of anything else you want on at the same time.

Can a 3,500 watt generator run a central air conditioner?

Not on its own. A central air conditioner alone needs a generator rated for about 9,000 running watts, and with a fridge, lights, laptop and router about 11,000 running watts.

Can a 2,000 watt generator run a central air conditioner?

Not on its own. With about 10,500 W at startup, check the generator's peak (starting) rating as well as its running rating.

Related sizes and guides

Estimates only. Results assume standard materials and simple shapes. Supplier products vary, and the final call on quantity, structure and safety is yours. Check your local code and your supplier's guidance before ordering.