How Many Steps for a 2,200 mm Rise?

A 2,200 mm rise needs 12 risers of 183.3 mm and 11 treads. With a 250 mm going the stair is 2.75 m long on plan at a pitch of 36.3°.

Jump to your result ↓

Your project

Results

Example job shown. Change the numbers to match yours.

Number of risers (steps up)
12 risers
11 treads, since the top step is the upper floor
Rise of each stepFloor to floor height ÷ the number of risers
183.3 mm
Going of each tread
250 mm
Pitch of the stairThe regulations allow up to 42° for a private stair
36.3 °
2 × rise + goingShould be between 550 and 700 mm
617 mm
Length of the stair on planThe going of the treads, without any landing
2.75 m
Meets Part K for a private stair?Rise up to 220 mm, going at least 220 mm, pitch up to 42°
Yes
  • These are the limits for a private (single-dwelling) stair in Approved Document K for England: a maximum rise of 220 mm, a minimum going of 220 mm, a maximum pitch of 42 degrees, and 2 × rise + going between 550 and 700 mm. The rise and going must be the same for every step in a flight (a tolerance of up to 5 mm is allowed between adjacent steps). You also need a clear headroom of 2.0 m above the pitch line, a handrail, and a guard where there is a drop. Building control approves new stairs, and the rules differ in Scotland, Wales and Northern Ireland.

Before you buy: round up to whole packs, check the size printed on the label, and add a little spare. Your supplier has the final say.

Steps for a 2,200 mm rise

A height of 2.2 m is typical for a loft hatch staircase or a mezzanine floor. Measure from the finished floor below to the finished floor above, which is the surface of the top step. The count below uses a 190 mm target rise and a 250 mm going.

ItemValue
Number of risers12
Rise of each step183.3 mm
Number of treads11
Going250 mm
Pitch36.3°
2 × rise + going617 mm
Length on plan2.75 m

Effect of the rise you choose

A taller rise means fewer steps but a steeper stair. Part K allows up to 220 mm for a private stair.

Target riseRisersActual risePitchLength on plan
220 mm10220.0 mm41.3°2.25 m
200 mm11200.0 mm38.7°2.50 m
190 mm12183.3 mm36.3°2.75 m
175 mm13169.2 mm34.1°3.00 m

Effect of the going

Deeper goings are gentler but need more floor space. The minimum going is 220 mm, and 2 × rise + going should be between 550 and 700 mm.

GoingPitch2 × rise + goingLength on plan
220 mm39.8°587 mm2.42 m
250 mm36.3°617 mm2.75 m
280 mm33.2°647 mm3.08 m
300 mm31.4°667 mm3.30 m

Use the UK stair calculator to enter your own height and going. Stairs are a safety item: you also need 2.0 m of headroom, a handrail and a guard where there is a drop, so check with building control.

Want to change anything else? The calculator above is the full Stair Calculator (UK): Rise, Going and Building Regulations: edit any number and the results update instantly.

Tools & materials for this project

Affiliate links As an Amazon Associate we earn from qualifying purchases. These links do not change what you pay.

Frequently asked questions

How many steps for a 2,200 mm rise?

12 risers (steps up), each 183.3 mm, with 11 treads because the upper floor is the top step. This uses a 190 mm target rise. A 220 mm rise, the steepest Part K allows, gives 10 risers.

How long is a staircase for 2.2 m floor to floor?

2.75 m on plan with a 250 mm going, before any landing. A shallower going makes the stair shorter but steeper.

Does a 2,200 mm rise meet Building Regulations?

With 12 risers of 183.3 mm and a 250 mm going, the pitch is 36.3° and 2 × rise + going is 617 mm. Part K for a private stair in England asks for a rise up to 220 mm, a going of at least 220 mm and a pitch up to 42°. Building control approves the final design.

Related sizes and guides

Related sizes

Estimates only. Results assume standard materials and simple shapes. Supplier products vary, and the final call on quantity, structure and safety is yours. Check your local code and your supplier's guidance before ordering.