Wood Burner Size Calculator (UK): What kW Stove Do I Need?

Enter the size of the room and how well it is insulated. You get the stove output in kW, the next common stove size, and the permanent air vent that Building Regulations may require.

UK edition. Switch to the US edition for feet, inches and US gallons.

Jump to your result ↓

Your project

Results

Example job shown. Change the numbers to match yours.

Stove output needed
3.4 kW
Room volume ÷ 14. 11,698 BTU/h
Room volume
48.0 m³
Next common stove sizeDo not go much over: an oversized stove overheats the room
4 kW
Permanent air vent needed (free area)None for a stove of up to 5 kW in a house that is not airtight
0 mm²
  • The rule of thumb is the room volume in cubic metres divided by 14 for an average room: by about 25 for a well-insulated modern room, and 10 for a poorly insulated one. It heats one room: a stove in an open-plan space heats the whole volume, and heat moves into rooms that are connected through open doors. Under Approved Document J (England), a permanent air vent is needed for a stove above 5 kW in an older house, and for any stove in a very airtight house. The stove must be installed by a HETAS-registered installer or with building control approval, and in a smoke control area it must be a DEFRA-exempt appliance.

Before you buy: round up to whole packs, check the size printed on the label, and add a little spare. Your supplier has the final say.

How this calculator works

A wood burner has to give out about as much heat as the room loses. The rule used by stove suppliers is to divide the volume of the room in cubic metres by 14 to get the kW needed for an average room with double glazing and cavity walls. A very well insulated room loses less heat, so the divisor is higher (about 25), and a draughty room with poor insulation loses more, so the divisor is lower (10). The nearest common stove size above that is the one to look at. Approved Document J of the Building Regulations also requires a permanent air vent of 550 mm² for each kW of output above 5 kW (and for each kW in a very airtight house) to supply the combustion air.

stove kW = room length × width × height ÷ 14 (average) air vent = 550 mm² × (stove kW − 5), or 550 mm² × stove kW in an airtight house

Worked example: a living room 5 × 4 m with a 2.4 m ceiling is 48 m³, which needs 3.4 kW, so a 4 kW stove. If the room is poorly insulated it needs 4.8 kW (5 kW), and if it is very well insulated 1.9 kW (3 kW). A larger 6 × 5 m lounge needs 5.1 kW and a long 8 × 4 m open-plan room with a 2.8 m ceiling needs 6.4 kW (7 kW stove, with 1,100 mm² of air vent). A 4 kW stove needs no vent in an older house, but 2,200 mm² in a very airtight one.

Stove size for common rooms (2.4 m ceiling)

The output in kW for average, very well insulated and poorly insulated rooms.

RoomVolumeAverageVery goodPoor
3 × 3 m22 m³1.5 kW0.9 kW2.2 kW
4 × 3.5 m34 m³2.4 kW1.3 kW3.4 kW
5 × 4 m48 m³3.4 kW1.9 kW4.8 kW
6 × 4 m58 m³4.1 kW2.3 kW5.8 kW
6 × 5 m72 m³5.1 kW2.9 kW7.2 kW
8 × 4 m77 m³5.5 kW3.1 kW7.7 kW

Tips before you buy

  • A stove that is too big is a common mistake: it makes the room too hot, and then is run on a low, smoky burn that blackens the glass. Choose the size for the room, not the biggest.
  • Better insulation and draught-proofing make a smaller stove work. Fix the heat loss first.
  • Open doorways let heat flow into the next room. If the stove is in an open-plan space, use the volume of the whole space.
  • Use dry, seasoned wood (below 20% moisture) or approved smokeless fuel, and have the chimney swept every year.
  • A carbon monoxide alarm is a must, and the stove needs a proper flue, a hearth and clearances to combustible materials.

Tools & materials for this project

Affiliate links As an Amazon Associate we earn from qualifying purchases. These links do not change what you pay.

Frequently asked questions

What size wood burner do I need for my room?

Divide the room volume in cubic metres by 14. A room of 5 × 4 × 2.4 m is 48 m³ and needs 3.4 kW, so a 4 kW stove.

What size room will a 5kW stove heat?

About 70 m³ of average room (29 m² of floor with a 2.4 m ceiling). It is more in a well-insulated room, and less in a draughty one.

Does my log burner need an air vent?

A stove above 5 kW needs a permanent air vent of 550 mm² for each kW above 5 kW in an older house, which is 1,100 mm² for the 7 kW stove for the long room. In a very airtight house every stove needs one, 2,200 mm² for a 4 kW stove.

Is it bad to have a stove that is too big?

Yes. A stove that is too big overheats the room, and is then run on a low, slow burn that makes smoke and soot and blackens the glass. Choose the size for the room.

Do I need a HETAS installer?

A stove must be installed by a HETAS-registered installer, or with building control approval, so that the work is signed off. In a smoke control area the stove must be DEFRA-exempt.

Add this calculator to your website

Running a blog, a contractor site or a class page? You can put this calculator on it for free. Copy the code below, and please leave the link underneath the calculator in place. The small script just resizes the frame to fit the results; if your site strips scripts, the calculator still works inside a scrolling frame.

Get the embed code

Related calculators & guides

Estimates only. Results assume standard materials and simple shapes. Supplier products vary, and the final call on quantity, structure and safety is yours. Check your local code and your supplier's guidance before ordering.