What Size Radiator for a 3 × 3 m Room?

A 3 × 3 m living room with a 2.4 m ceiling, double glazing and one external wall needs a radiator giving about 1,188 W (4,053 BTU/h) at ΔT50. As a bedroom, heated to 18°C, it needs 1,039 W. On a heat pump, look for about 2,308 W at ΔT50.

Jump to your result ↓

Your project

Results

Example job shown. Change the numbers to match yours.

Heat the room needs
1,188 W
1.19 kW, for a room of 21.6 m³
In BTU per hourRadiators are often sold by BTU
4,053 BTU/h
Radiator output to look for (boiler, ΔT50)The output shown at ΔT50, for a flow of about 75°C. Choose the next size up
1,188 W
Same room on a low-temperature heat pump (ΔT30)Output as shown at ΔT50 on the radiator label, since it gives only about 51% of that at ΔT30
2,308 W
Heat per cubic metre
55.0 W/m³
Room volume
21.6 m³
  • This is a quick estimate from the volume, with adjustments for the room temperature you want, the glazing, the number of external walls and the insulation. A room-by-room heat loss calculation (as an installer or a heat pump designer does) is more accurate, especially for a heat pump. Radiators are rated at ΔT50 (the radiator 50°C above the room); at a lower flow temperature the output falls steeply, so heat pump systems need larger radiators.

Before you buy: round up to whole packs, check the size printed on the label, and add a little spare. Your supplier has the final say.

Radiator size for a 3 × 3 m room, by type of room

A 3 × 3 m room is a single bedroom, a study or a small dining room. The floor area is 9 m² and, with a 2.4 m ceiling, the volume is 21.6 m³. These figures assume double glazing, one external wall and filled cavity walls. The last column is the ΔT50 rating to look for if a heat pump supplies the radiators.

RoomHeat neededBTURating for a heat pump (ΔT50)
Living room (21°C)1,188 W4,053 BTU/h2,308 W
Bedroom (18°C)1,039 W3,547 BTU/h2,019 W
Kitchen (18°C)1,039 W3,547 BTU/h2,019 W
Hall or landing (16°C)940 W3,209 BTU/h1,827 W
Bathroom (22°C)1,237 W4,222 BTU/h2,404 W

External walls and insulation

Every outside wall loses heat, and solid walls lose more than insulated ones. Living room at 21°C, double glazing, 2.4 m ceiling.

External wallsSolid walls, not insulatedCavity walls, filledWell insulated
None (an inside room)1,212 W1,010 W858 W
One1,426 W1,188 W1,010 W
Two (a corner room)1,639 W1,366 W1,161 W
Three or more1,782 W1,485 W1,262 W

Taller ceilings

A taller room holds more air to heat. Living room, double glazing, one external wall.

Ceiling heightRoom volumeHeat neededBTU
2.4 m21.6 m³1,188 W4,053 BTU/h
2.7 m24.3 m³1,337 W4,560 BTU/h
3.0 m27.0 m³1,485 W5,067 BTU/h

One radiator or two?

1,188 W is comfortably within the range of a single double-panel radiator, usually placed under the window, where it counters the cold air falling from the glass. Pick the next size up from the figure, at ΔT50.

These are quick estimates from the room volume. For a heat pump, or a room with large windows, ask an installer for a room-by-room heat loss calculation. The radiator size guide explains ΔT ratings, and the boiler size calculator sizes the whole system.

Want to change anything else? The calculator above is the full Radiator Size Calculator (UK, Watts and BTU): edit any number and the results update instantly.

Tools & materials for this project

Affiliate links As an Amazon Associate we earn from qualifying purchases. These links do not change what you pay.

Frequently asked questions

What size radiator do I need for a 3 × 3 m room?

About 1,188 W (4,053 BTU/h) for a living room with double glazing, one external wall, cavity wall insulation and a 2.4 m ceiling. The same room as a bedroom, heated to 18°C, needs 1,039 W.

How many BTU to heat a 3 × 3 m room?

4,053 BTU/h for a living room, or 3,547 BTU/h for a bedroom. A cold corner room with solid walls and single glazing needs 6,713 BTU/h.

What radiator size for a 3 × 3 m room with a heat pump?

A heat pump runs at a lower flow temperature, so the radiators give less heat. Choose a radiator rated about 2,308 W at ΔT50 for a living room this size (it gives about 1,188 W at ΔT30), or 2,019 W for a bedroom.

Related sizes and guides

Related sizes

Estimates only. Results assume standard materials and simple shapes. Supplier products vary, and the final call on quantity, structure and safety is yours. Check your local code and your supplier's guidance before ordering.