What Size Radiator for a 5 × 5 m Room?

A 5 × 5 m living room with a 2.4 m ceiling, double glazing and one external wall needs a radiator giving about 3,300 W (11,260 BTU/h) at ΔT50. As a bedroom, heated to 18°C, it needs 2,888 W. On a heat pump, look for about 6,411 W at ΔT50.

Jump to your result ↓

Your project

Results

Example job shown. Change the numbers to match yours.

Heat the room needs
3,300 W
3.30 kW, for a room of 60.0 m³
In BTU per hourRadiators are often sold by BTU
11,260 BTU/h
Radiator output to look for (boiler, ΔT50)The output shown at ΔT50, for a flow of about 75°C. Choose the next size up
3,300 W
Same room on a low-temperature heat pump (ΔT30)Output as shown at ΔT50 on the radiator label, since it gives only about 51% of that at ΔT30
6,411 W
Heat per cubic metre
55.0 W/m³
Room volume
60.0 m³
  • This is a quick estimate from the volume, with adjustments for the room temperature you want, the glazing, the number of external walls and the insulation. A room-by-room heat loss calculation (as an installer or a heat pump designer does) is more accurate, especially for a heat pump. Radiators are rated at ΔT50 (the radiator 50°C above the room); at a lower flow temperature the output falls steeply, so heat pump systems need larger radiators.

Before you buy: round up to whole packs, check the size printed on the label, and add a little spare. Your supplier has the final say.

Radiator size for a 5 × 5 m room, by type of room

A 5 × 5 m room is a large living room or a kitchen-diner. The floor area is 25 m² and, with a 2.4 m ceiling, the volume is 60.0 m³. These figures assume double glazing, one external wall and filled cavity walls. The last column is the ΔT50 rating to look for if a heat pump supplies the radiators.

RoomHeat neededBTURating for a heat pump (ΔT50)
Living room (21°C)3,300 W11,260 BTU/h6,411 W
Bedroom (18°C)2,888 W9,852 BTU/h5,610 W
Kitchen (18°C)2,888 W9,852 BTU/h5,610 W
Hall or landing (16°C)2,613 W8,914 BTU/h5,075 W

External walls and insulation

Every outside wall loses heat, and solid walls lose more than insulated ones. Living room at 21°C, double glazing, 2.4 m ceiling.

External wallsSolid walls, not insulatedCavity walls, filledWell insulated
None (an inside room)3,366 W2,805 W2,384 W
One3,960 W3,300 W2,805 W
Two (a corner room)4,554 W3,795 W3,226 W
Three or more4,950 W4,125 W3,506 W

Taller ceilings

A taller room holds more air to heat. Living room, double glazing, one external wall.

Ceiling heightRoom volumeHeat neededBTU
2.4 m60.0 m³3,300 W11,260 BTU/h
2.7 m67.5 m³3,713 W12,667 BTU/h
3.0 m75.0 m³4,125 W14,075 BTU/h

One radiator or two?

At 3,300 W, a room this size is often better with two radiators, one under each window or on facing walls, which spreads the heat and keeps each radiator a sensible size. Add up the ΔT50 outputs printed on the radiators so the total meets the figure.

These are quick estimates from the room volume. For a heat pump, or a room with large windows, ask an installer for a room-by-room heat loss calculation. The radiator size guide explains ΔT ratings, and the boiler size calculator sizes the whole system.

Want to change anything else? The calculator above is the full Radiator Size Calculator (UK, Watts and BTU): edit any number and the results update instantly.

Tools & materials for this project

Affiliate links As an Amazon Associate we earn from qualifying purchases. These links do not change what you pay.

Frequently asked questions

What size radiator do I need for a 5 × 5 m room?

About 3,300 W (11,260 BTU/h) for a living room with double glazing, one external wall, cavity wall insulation and a 2.4 m ceiling. The same room as a bedroom, heated to 18°C, needs 2,888 W.

How many BTU to heat a 5 × 5 m room?

11,260 BTU/h for a living room, or 9,852 BTU/h for a bedroom. A cold corner room with solid walls and single glazing needs 18,646 BTU/h.

What radiator size for a 5 × 5 m room with a heat pump?

A heat pump runs at a lower flow temperature, so the radiators give less heat. Choose a radiator rated about 6,411 W at ΔT50 for a living room this size (it gives about 3,300 W at ΔT30), or 5,610 W for a bedroom.

Related sizes and guides

Related sizes

Estimates only. Results assume standard materials and simple shapes. Supplier products vary, and the final call on quantity, structure and safety is yours. Check your local code and your supplier's guidance before ordering.