Boiler Size Calculator (UK): What kW Boiler Do I Need?

Enter the size of the home, how well it is insulated and how much hot water you use at once. You get the heat the house needs, the hot water power, and the boiler size to look for, for a combi or a system boiler.

UK edition. Switch to the US edition for feet, inches and US gallons.

Jump to your result ↓

Your project

Results

Example job shown. Change the numbers to match yours.

Boiler output to look for
24 kW
The next standard size above 20.9 kW
Heat the home needs on a cold day70 W per m² of floor
7.0 kW
Power to heat the hot water1 outlet at 10 litres a minute, heated by 30°C
20.9 kW
Load the boiler must meetThe larger of the heating and the hot water
20.9 kW
  • A combi boiler heats the hot water directly, so its output is set mostly by the hot water you want at once, which is why a 24 to 30 kW combi suits a house that needs only 7 kW for heating: a modern boiler turns down (modulates) to run at a low output for the radiators. A system or regular boiler stores hot water in a cylinder, so it is sized for the heating. This is a rule-of-thumb estimate: ask a Gas Safe registered engineer for a room-by-room heat loss calculation, and size radiators with the radiator size calculator.

Before you buy: round up to whole packs, check the size printed on the label, and add a little spare. Your supplier has the final say.

How this calculator works

A boiler has two jobs. It heats the radiators, and it heats the hot water. The heating load is the heat the home loses on a cold day, which we estimate from the floor area and how well it is insulated: about 70 watts per square metre for an average home, 100 for a poorly insulated one and 30 for an excellent new build. A combi boiler also heats the hot water as it runs, using a power of the flow in litres a minute times the temperature rise (30°C) times 0.0697 kW. It cannot heat the radiators and run a shower at once, so it must meet the larger of the two. A system or regular boiler stores hot water in a cylinder, so it is sized for the heating, with about 10% extra to reheat the cylinder.

heating kW = floor area × watts per m² ÷ 1000 hot water kW = litres per minute × 30°C × 0.0697 combi = the larger of the two

Worked example: a 100 m² home with average insulation needs 7.0 kW for heating. One shower at 10 litres a minute needs 20.9 kW of hot water, so a combi has to be at least 20.9 kW: a 24 kW combi. With two outlets at once it is 41.8 kW (42 kW). A system boiler for the same house is 12 kW (7.7 kW with the cylinder allowance). A 200 m² home needs 14.0 kW and a 24 kW system boiler, a poorly insulated 100 m² home needs 10.0 kW, and an excellent new build only 3.0 kW.

Heat needed by home size (average insulation, 70 W per m²)

The heating load and the combi and system boiler sizes.

Floor areaHeat neededCombi (1 shower)System boiler
50 m²3.5 kW24 kW12 kW
75 m²5.3 kW24 kW12 kW
100 m²7.0 kW24 kW12 kW
125 m²8.8 kW24 kW12 kW
150 m²10.5 kW24 kW12 kW
200 m²14.0 kW24 kW18 kW
250 m²17.5 kW24 kW24 kW

Tips before you buy

  • The heat the house needs and the hot water you use at once are two separate sums. A combi boiler has to meet the larger of the two, but a system boiler with a cylinder is sized for the heating.
  • A bigger boiler is not better. An oversized boiler cycles on and off and wears faster, but modern boilers modulate down to a fraction of their output.
  • Better insulation and draught-proofing are cheaper than a bigger boiler, and cut the size you need.
  • A combi boiler struggles to supply two showers at once. If you have several bathrooms, a system boiler with a cylinder is a better fit.
  • Boiler and gas work must be done by a Gas Safe registered engineer.

Tools & materials for this project

Affiliate links As an Amazon Associate we earn from qualifying purchases. These links do not change what you pay.

Frequently asked questions

What size boiler do I need for my house?

For a 100 m² home with average insulation, the heating needs 7.0 kW. A combi must also meet the hot water, so it is a 24 kW combi for one shower at a time, or a 12 kW system boiler with a cylinder.

What size combi boiler for a 3 bedroom house?

A 3 bedroom house of about 100 m² with one bathroom usually needs a 24 to 30 kW combi: 24 kW here. With two bathrooms and two showers at once it is 42 kW.

Is a 24kW combi enough?

For one shower at a time, yes: it supplies about 11 litres a minute at a 30°C rise. For two showers at once you need a 30 to 35 kW combi, or a system boiler with a cylinder.

Why is the boiler bigger than the heat the house needs?

Because a combi must supply hot water on demand as well. The house needs only 7.0 kW for heating, but one shower needs 20.9 kW. A modern boiler modulates down, so it runs at a low output for the radiators.

Does a bigger boiler cost more to run?

Not by itself: a boiler uses gas in proportion to the heat it produces. But an oversized boiler that cycles on and off can be less efficient, so choose the size for the load.

Add this calculator to your website

Running a blog, a contractor site or a class page? You can put this calculator on it for free. Copy the code below, and please leave the link underneath the calculator in place. The small script just resizes the frame to fit the results; if your site strips scripts, the calculator still works inside a scrolling frame.

Get the embed code