Heater size for a 30 × 40 ft garage, by insulation
An 8 ft ceiling, holding 50°F when it is 20°F outside, with a 25% margin. Amps are at 240 V for the standard electric size.
| Insulation | BTU per hour | Watts | Electric size | Amps |
|---|---|---|---|---|
| None: bare studs, plain door | 48,870 BTU | 14,323 W | 15,000 W | 62.5 A |
| Walls and ceiling insulated | 23,880 BTU | 6,999 W | 7,500 W | 31.3 A |
| Well insulated, door too | 12,588 BTU | 3,689 W | 4,000 W | 16.7 A |
How cold it gets where you live
The same garage with insulated walls and ceiling, held at 50°F, for different design temperatures outside:
| Coldest outdoor temperature | Heat needed | Electric size |
|---|---|---|
| 0°F | 39,800 BTU | 15,000 W |
| 10°F | 31,840 BTU | 10,000 W |
| 20°F | 23,880 BTU | 7,500 W |
| 30°F | 15,920 BTU | 5,000 W |
How warm you want it
At 20°F outside, insulated. The last column is the cost per hour at 17¢ a kWh if the heater runs non-stop at the heat-loss rate:
| Temperature inside | Heat needed | Electric size | Cost per hour |
|---|---|---|---|
| 40°F | 15,920 BTU | 5,000 W | $0.79 |
| 50°F | 23,880 BTU | 7,500 W | $1.19 |
| 60°F | 31,840 BTU | 10,000 W | $1.59 |
| 70°F | 39,800 BTU | 15,000 W | $1.98 |
A 30 × 40 ft garage or pole barn shop
A 30 × 40 ft building is a big shop. Insulated, with an 8 ft ceiling, it needs 23,880 BTU (6,999 W). Shops are often taller, and a 12 ft ceiling raises that to 31,320 BTU.
At this size gas, propane or a ducted system is usually cheaper to run than electric heat. If you choose a fuel-burning heater, it must be vented or rated for the space, with a carbon monoxide alarm.
Enter your own garage in the garage heater size calculator, or read what size heater for a garage for breakers, fuel and safety.
Want to change anything else? The calculator above is the full Garage Heater Size Calculator: edit any number and the results update instantly.
Tools & materials for this project
Affiliate links As an Amazon Associate we earn from qualifying purchases. These links do not change what you pay.
Frequently asked questions
What size heater for a 30 × 40 ft garage?
About 23,880 BTU, or 6,999 W, to hold 50°F when it is 20°F outside, with insulated walls and ceiling and an 8 ft ceiling. That is a 7,500 W electric heater. With no insulation it needs 48,870 BTU.
How many amps does a heater for a 30 × 40 garage draw?
A 7,500 W heater draws 31.3 amps at 240 V. The breaker must be rated for 125% of that, and the wire sized to the breaker.
How much does it cost to heat a 30 × 40 ft garage?
About $1.19 an hour at 17¢ a kWh if the heater ran non-stop at the heat-loss rate. In practice the thermostat cycles it, and a garage you heat only while you work costs far less.
Will a 1,500 W space heater heat a 30 × 40 garage?
A 1,500 W heater gives 5,118 BTU an hour. That is not enough even when the garage is well insulated (12,588 BTU). It will take the chill off a small area near you.
Related sizes and guides
Related sizes
Estimates only. Results assume standard materials and simple shapes. Supplier products vary, and the final call on quantity, structure and safety is yours. Check your local code and your supplier's guidance before ordering.